| Type | EtherCAT communication
function not provided |
EtherCAT communication
function provided |
|||
|---|---|---|---|---|---|
| Color | Monochrome | Color | Monochrome | ||
| Model | NPN | FQ-MS120 | FQ-MS120-M | FQ-MS120-ECT | FQ-MS120-M-ECT |
| PNP | FQ-MS125 | FQ-MS125-M | FQ-MS125-ECT | FQ-MS125-M-ECT | |
| Field of vision, Installation distance | Selecting a lens according to the field of vision and installation distance. Refer
to the "Optical Chart" on Catalog. |
||||
| Main
functions |
Inspection items | Shape search, Search, Labeling, Edge position | |||
| Number of simultaneous
inspections |
32 | ||||
| Number of registered
scenes |
32 *1 | ||||
| Image
input |
Image processing
method |
Real color | Monochrome | Real color | Monochrome |
| Image elements | 1/3-inch color CMOS | 1/3-inch
monochrome CMOS |
1/3-inch color CMOS | 1/3-inch
monochrome CMOS |
|
| Image filter | High dynamic
range (HDR) and white balance |
High dynamic
range (HDR) |
High dynamic
range (HDR) and white balance |
High dynamic
range (HDR) |
|
| Shutter | Electronic shutter; select shutter speeds from 1/10 to 1/30000 (sec) | ||||
| Processing resolution | 752 (H) ✕ 480 (V) | ||||
| Pixel size | 6.0 (μm) ✕ 6.0 (μm) | ||||
| Frame rate
(image read time) |
60fps (16.7ms) | ||||
| External
Lightings |
Connecting method | Connection via a strobe light controller | |||
| Connectable lighting | FL series | ||||
| Data
logging |
Measurement data | In Sensor: Max. 32000 items *2 | |||
| Images | In Sensor: 20 images *2 | ||||
| Measurement trigger | I/O trigger, Encoder trigger, Communications trigger (Ethernet No-protocol,
PLC Link, or EtherCAT) |
||||
| I/O
specifi- cations |
Input signals | 9 signals
Single measurement input (TRIG) Error clear input (IN0) Encoder counter reset input (IN1) Encoder input (A±, B±, Z±) *4 |
|||
| Output signals | 5 signals *3
OUT0 Overall judgement output (OR) OUT1 Control output (BUSY) OUT2 Error output (ERROR) OUT3 (Shutter output: SHTOUT) OUT4 (Strobe trigger output: STGOUT) |
||||
| Ethernet specifications | 100BASE-TX/10BASE-TX | ||||
| EtherCAT specifications | --- | Dedicated protocol for EtherCAT 100BASE-TX | |||
| Connection method | Special connector cables
Power supply and I/O: 1 special connector I/O cable Touch Finder, Computer and Ethernet: 1 Ethernet cable EtherCAT: 2 EtherCAT cable |
||||
| LED
display |
OR: Judgment result indicator
ERR: Error indicator BUSY: BUSY indicator ETN: Ethernet communications indicator |
||||
| EtherCAT display | --- | L/A IN (Link/Activity IN) ✕ 1
L/A OUT (Link/Activity OUT) ✕ 1 RUN ✕ 1 ERR ✕ 1 |
|||
| Ratings | Power supply voltage | 21.6 to 26.4 VDC (including ripple) | |||
| Insulation resistance | Between all lead wires and case: 0.5 MΩ (at 250 V) | ||||
| Current consumption | 450mA max. (When the FL-series Strobe controller and lighting are used.)
250mA max. (When external lighting is not used.) |
||||
| Environ-
mental immunity |
Ambient temperature
range |
Operating: 0 to 50 °C, Storage: -20 to 65 °C (with no icing or condensation) | |||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Ambient atmosphere | No corrosive gas | ||||
| Vibration resistance
(destruction) |
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions, 8 min each, 10 times | ||||
| Shock resistance
(destruction) |
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward) | ||||
| Degree of protection | IEC60529 IP40 | ||||
| Materials | Case: alminium die casting, Rear cover: alminium plate | ||||
| Weight | Approx. 390 g (Sensor only) | Approx. 480 g (Sensor only) | |||
| Accessories | Instruction Manual | ||||