| Degree of protection *1 | IP67 (EN60947-5-1) | |
|---|---|---|
| Durability *2 | Mechanical | 15,000,000 operations min. *5 |
| Electrical | 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) |
|
| Operating speed | 1 to 500 mm/s (D4N-1120) | |
| Operating frequency | 30 operations/minute max. | |
| Contact resistance | 25 mΩ max. | |
| Minimum applicable load *4 | 1 mA resistive load at 5 VDC (N-level reference value) | |
| Rated insulation voltage (Ui) | 300 V | |
| Rated frequency | 50/60 Hz | |
| Protection against electric shock | Class II (double insulation) | |
| Pollution degree (operating environment) | 3 (EN60947-5-1) | |
|
Impulse withstand voltage (EN60947-5-1) |
Between terminals of same polarity | 2.5 kV |
|
Between terminals of different polarity |
4 kV | |
|
Between each terminal and non- current carrying metallic parts |
6 kV | |
| Insulation resistance | 100 MΩ min. | |
| Contact gap | Snap-action: 2 × 0.5 mm min. Slow-action: 2 × 2 mm min. |
|
| Vibration resistance | Malfunction | 10 to 55 Hz, 0.75 mm single amplitude |
| Shock resistance | Destruction | 1,000 m/s2 min. |
| Malfunction | 300 m/s2 min. | |
| Conditional short-circuit current | 100 A (EN60947-5-1) | |
| Conventional free air thermal current (Ith) | 10 A (EN60947-5-1) | |
| Ambient operating temperature | -30 to 70°C (with no icing) | |
| Ambient operating humidity | 95% max. | |
| Weight | Approx. 82 g (D4N-1120) Approx. 99 g (D4N-6120) |
|