| Sensing method | Retro-reflective | Retro-reflective
(with MSR function ) *1 |
Retro-reflective | |||
|---|---|---|---|---|---|---|
| Model | NPN | E3S-R12, R62,
R17, R67 |
E3S-R11, R16, R61, R66 | E3S-RS30E4,
RS30E42 |
E3S-R1E4, R1E42 | |
| PNP | --- | E3S-R31, R36, R81, R86 | --- | --- | ||
| Sensing distance | 300 mm [100 mm] *2
(When using E39-R1) |
1 m [100 mm] *2
(When using E39-R1) |
300 mm
(When using E39-R1) |
1 m
(When using E39-R1) |
||
| Standard sensing
object |
Opaque: 75-mm dia.
min. 0.7-mm-thick LCD glass boards; 10-mm-dia., 1.0- mm-thick, 30-mm- long cylindrical glass objects |
Opaque: 75-mm dia. min.
0.7-mm-thick LCD glass boards |
Opaque: 75-mm dia. min.
10-mm-dia., 1.0-mm-thick, 30-mm-long cylindrical glass objects |
|||
| Directional angle | 3° to 10° | --- | ||||
| Light source (wavelength) | Infrared LED (880 nm) | Red LED (700 nm) | Infrared LED (950 nm) | |||
| Power supply
voltage |
10 to 30 VDC; ripple: 10% max. | 12 to 24 VDC±10%; ripple: 10% max. | ||||
| Current
consumption |
30 mA max. | 40 mA max. | ||||
| Control output | Load power supply voltage: 30 VDC max.
Load current: 100 mA max. with a maximum residual voltage of 1 V Open collector output configuration Light-ON/Dark-ON selector switch |
Load power supply voltage: 24 VDC max
Load current: 80 mA max. with a maximum residual voltage of 2 V NPN voltage output configuration Light-ON/Dark-ON cable connection selection |
||||
| Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, Mutual interference prevention | |||||
| Response time | Operate or reset: 1 ms max. | |||||
| Sensitivity
adjustment |
Two-turn endless adjuster | One-turn adjuster | ||||
| Ambient
illumination (Receiver side) |
Incandescent lamp: 5,000 lx max.
Sunlight: 10,000 lx max. |
Incandescent lamp: 3,000 lx max.
Sunlight: 10,000 lx max. |
||||
| Ambient
temperature range |
Operating: 0 to 40°C, Storage: -40 to 70°C (with no icing or condensation) | Operating: - 25 to 55° C
Storage: -40 to 70° C (with no icing or condensation) |
||||
| Ambient
humidity range |
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation) | |||||
| Insulation
resistance |
20 MΩ min. (at 500 VDC) | |||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 min | |||||
| Vibration
resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 h each in X, Y, and Z directions | |||||
| Shock resistance | Destruction: 500 m/s2 for 3 times each in X, Y, and Z directions | |||||
| Degree of
protection |
IEC 60529 IP67 | |||||
| Connection
method |
Pre-wired (standard length: 2 m)/Standard connector | |||||
| Weight
(packed state) |
Pre-wired models: Approx. 110 g
Standard connector: Approx. 60 g |
Pre-wired models: Approx. 190 g | ||||
| Ma-
teri- als |
Case | Polybutylene terephthalate | Zinc die-cast | |||
| Lens | Modified polyallylate | Polycarbonate | ||||
| Mounting
Bracket |
Stainless steel (SUS304) | Iron | ||||
| Accessories | Mounting Bracket (with screw), Adjustment screwdriver, Instruction manual, Reflector | Mounting Bracket (with screw),
Adjustment screwdriver, Sensitivity adjuster, Instruction manual, Reflector |
||||
*2. Values in parentheses indicate the minimum required distance between the Sensor and Reflector.