Pull-reset Safety Limit Switch
Image
| Shape/Structure |
Safety limit switches |
|---|---|
| Actuator |
One-way action roller arm lever 12.5 dia. * 5 POM roller 19 R |
| Operation type |
Vertical operation type |
| Contact configuration |
Double break type |
| Load |
General load / Micro load |
| Degree of protection |
IEC60529 (JEM): IP67 NEMA250: Type4X Indoor Use Only |
As of August 8, 2016
| Shape/Structure | Safety limit switches |
|---|---|
| Service life | General type |
| Operating mechanism | Slow action |
| Actuator | One-way action roller arm lever 12.5 dia. * 5 POM roller 19 R |
| Operation type | Vertical operation type |
| Frequency | 50/60 Hz |
| Contact configuration | Double break type |
| Contact form | 1NC / 1NO |
| Load | General load / Micro load |
| Protective circuit | Classification of protection against electric shock: Class II (Double insulation) Short-circuit protective device: 10 A fuse type gI or gG (IEC269) |
| Conduit size | G1/2 |
| Number of conduit | 1 |
| Earth terminal | Without ground terminal |
| Ambient temperature | Operating: -30 to 70 ℃ Storage: -30 to 70 ℃ |
| Ambient humidity | 使用時: 95%以下 |
| Permissible operating speed | 1 mm/s to 500 mm/s |
|---|---|
| Permissible operating frequency (Mechanically) | 30 operations / 1 minute Max. |
| Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
| Contact resistance | 25 mOhm Max. (Initial value) (Measuring method is contact resistance meter.) |
| Insulation resistance | Between each terminal of the same polarities: 100 MΩ Between each terminal of the different polarities (Between switch terminals): 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger) |
| Dielectric strength | Between each terminal of the same polarities: 2100 V Between each terminal of the different polarities (Between switch terminals): 3500 V Between each terminal and non-live-metallic part: 5300 V (VAC. r.m.s.) |
| Durability (Mechanically) | 1,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
| Durability (Electrically) | 300,000 operations Min. (Resistive load 10 A at 250 VAC) 500,000 operations Min. (Resistive load 3 A at 250 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
| Pollution degree | 3 (EN60947-5-1) |
| Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
| Shock resistance (Destruction) | 1,000 m/s2 |
| Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
| Degree of protection | IEC60529 (JEM): IP67 NEMA250: Type4X Indoor Use Only |
| Mounting specification | Front mounting |
| Locking force (LF) | Standard value Max. 7.9N |
|---|---|
| Locking travel (LT) | Standard value Max. 7 mm |
| Pre-Travel (PT) | Standard value 4 mm Max. |
| Operating Position (OP) | Standard value 27 +/- 0.8 mm |
| Total Travel (TT) | Reference value 9 mm |
As of August 8, 2016
As of August 8, 2016

As of August 8, 2016
As of August 8, 2016

As of August 8, 2016
about this Product