Power Relay
Image
| Coil ratings |
200 VAC 9 mA (50/60 Hz) / 240 VAC 10.8 mA (50/60 Hz) |
|---|---|
| Contact type |
4PST-NO |
| Contact method |
Double break |
| Contact material |
Ag alloy |
| Contact rated load |
220 VAC 25 A (Resistive load) 220 VAC 25 A (Inductive load (cos φ= 0.4)) 30 VDC 25 A (Resistive load) |
| Maximum switching current |
AC: 25 A DC: 25 A |
| Terminal structure |
PCB terminal |
As of February 2, 2017
| Product classification | Monostable relays Standard type |
|---|---|
| Coil ratings | 200 VAC 9 mA (50/60 Hz) / 240 VAC 10.8 mA (50/60 Hz) |
| Operate voltage (Set voltage) | 75 % max. |
| Release voltage (Reset voltage) | 15 % min. |
| Max. voltage | 110 % max. (of rated voltage) |
| Power consumption | Approx. 1.8 to 2.6 VA |
| Contact type | 4PST-NO |
| Contact method | Double break |
| Contact material | Ag alloy |
| Contact rated load | 220 VAC 25 A (Resistive load) 220 VAC 25 A (Inductive load (cos φ= 0.4)) 30 VDC 25 A (Resistive load) |
| Maximum switching voltage | 250 VAC 125 VDC |
| Maximum switching current | AC: 25 A DC: 25 A |
| Maximum switching power | 5500 VA (Resistive load) 5500 VA (Inductive load (cos φ= 0.4)) 750 W (Resistive load) |
| Failure rate | 100 mA at 24 VDC (failure level: P Reference value) (Switching frequency of 60 operations per minute) |
| Ambient temperature (Operating) | -25 to 60 ℃ (with no icing or condensation) |
| Ambient_humidity (Operating) | 5 to 85%RH (with no icing or condensation) |
| Contact resistance | 100 mΩ max., Measuring the voltage drop across the contacts by applying test voltage/current as 5 VDC 1 A |
| Release time (Reset time) | 50 ms max. (The operate or release time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23 ℃) |
| Insulation resistance | Between coil and contacts: 1000 MΩ min. (at 500 VDC) Between contacts of different polarity: 1000 MΩ min. (at 500 VDC) Between contacts of same polarity: 1000 MΩ min. (at 500 VDC) |
| Dielectric strength | Between coil and contacts: 4000 VAC (50/60 Hz 1 min) Between contacts of different polarity: 4000 VAC (50/60 Hz 1 min) Between contacts of same polarity: 2000 VAC (50/60 Hz 1 min) |
| Vibration resistance (Destruction) | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Vibration resistance (Malfunction) | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) |
| Shock resistance (Destruction) | 1000 m/s**2 |
| Shock resistance (Malfunction) | 100 m/s**2 |
| Endurance (Mechanical) | 1,000,000 operations min. (switching frequency 1,800 operations/h) |
| Endurance (Electrical) | 100,000 operations min. (23 ℃, switching frequency 1,800 operations/h) |
| Protective structure | Closed type (cover) |
| Terminal structure | PCB terminal |
| Weight | Approx. 140 g |
As of February 2, 2017
As of February 2, 2017


As of February 2, 2017
As of February 2, 2017
As of February 2, 2017
As of February 2, 2017
Electrical life
As of February 2, 2017
about this Product