Switch Mode Power Supply (15/30/50/100/150/300/600/1,500-W Models)
Image
| Power rating |
600 W |
|---|---|
| Rated input voltage |
100 to 240 VAC |
| Output voltage |
24 VDC |
| Heat radiation |
Forced air-cooling |
| Construction |
Covered type |
| Mounting type |
Bottom-mounting type |
As of October 10, 2016
| Power rating | 600 W |
|---|---|
| Efficiency | 81 % Min. |
| Rated input voltage | 100 to 240 VAC |
| Allowable input voltage variable range | 85 to 264 VAC |
| Frequency | 50/60 Hz(47 to 63 Hz Single-phase) |
| Rated input curren | 8.3A Max. (At 100 VAC input) 4.2A Max. (At 200 VAC input) |
| Power factor | 0.98 Min. (At 100 VAC input) 0.94 Min. (At 200 VAC input) |
| Leakage current | 0.4 mA Max. (At 100 VAC input) 0.75 mA Max. (At 200 VAC input) |
| Inrush current | 20 A Max. (At 100 VAC input (For cold start at 25 CEL)) 40 A Max. (At 200 VAC input (For cold start at 25 CEL)) |
| Output voltage | 24 VDC |
| Output voltage variable range | -20 to +20 % (With V. ADJ) (The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.) |
| Ripple | 1.25%(p-p) Max. |
| Static input variation influence | 0.4% Max. At 85 to 264 VAC input, 100% load |
| Static load variation influence | 0.6% Max. At rated input, 0 to 100% load |
| Ambient temperature variation influence | 0.02 %/CEL Max. (At rated input/output voltage) |
| Rated output current | 27 A / 31 A (Peak current at 200 VAC) |
| Start up time | 1000 ms Max. (At rated input/output voltage) |
| Hold time | 20ms TYP. |
| Overload protection | 115% to 160% of the rated output current Inverted L voltage drop, Automatic reset |
| Overvoltage protection | Operated at 125 to 145 % of the rated output voltage, Shut-off Resetting: Reset the power by turning it back (OFF time: at least 1 min) |
| Overheat protection | Yes Resetting: Reset the power by turning it back (OFF time: at least 3 min) Alternatively, turn OFF the remote control signal and then turn it back ON again |
| Maintenance forecast monitor output | No |
| Total run time monitor output | No |
| Undervoltage alarm output | No |
| Power failure alarm indication | Yes (color: red) |
| Power failure alarm output | Yes (open collector output), 30 VDC Max., 50 mA Max. |
| Parallel operation | Yes (Up to 2 Power Supplies) |
| Series operation | Yes (Up to 2 Power Supplies with external diode) |
| Remote sensing function | Yes |
| Dielectric strength | Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA) Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA) Between all outputs and PE terminals: 500 VAC for 1 min (Detection current: 100 mA) Between all outputs and RC terminals: 100 VAC for 1 min (Detection current: 100 mA) Between all outputs and PF terminals: 500 VAC for 1 min (Detection current: 20 mA) |
| Insulation resistance | Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC) |
| Vibration resistance | 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours |
| Shock resistance | 150 m/s**2, in each 6 directions 3 times |
| Output indicator | Yes (color: green) |
| Heat radiation | Forced air-cooling |
| Construction | Covered type |
| Mounting type | Bottom-mounting type |
| Attachment | Instruction manual |
Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning.
As of October 10, 2016