High-precision Switch
Image
| Shape/Structure |
High-precision switches |
|---|---|
| Actuator |
Plunger |
| Electrical ratings |
10 mA at 24 VAC 10 mA at 12 VDC |
| Contact configuration |
Normally Close type |
| Load |
General load |
| Cable specifications |
Oil-resistant cable 2 cores (Cable length: 1 m) Diameter: 3 mm dia. |
| Degree of protection |
IEC60529 (JEM): IP40 |
As of August 8, 2016
| Shape/Structure | High-precision switches |
|---|---|
| Service life | General type |
| Operating mechanism | Slow action |
| Actuator | Plunger |
| Electrical ratings | 10 mA at 24 VAC 10 mA at 12 VDC |
| Frequency | 50/60 Hz |
| Switching mechanism | Self-reset mechanism |
| Contact configuration | Normally Close type |
| Contact form | SPST-NC |
| Load | General load |
| Cable specifications | Oil-resistant cable 2 cores (Cable length: 1 m) Diameter: 3 mm dia. |
| Ambient temperature | Operating: -20 to 75 ℃ |
| Ambient humidity | Operating: 30 to 85% |
| Operating Position repeat accuracy | Standard value: 1 um Max. |
|---|---|
| Deviation after 1,000,000 operations of Electrical durability | 10 um Max. |
| Temperature index | Standard value: +/- 20 * 10-6/ CEL Max. the deviation rate of the operating position per 1 CEL of ambient temperature |
| Permissible operating speed | 1 um/s to 0.5 m/s |
| Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
| Permissible operating frequency (Electrically) | 60 operations / 1 minute Max. |
| Contact resistance | 800 mOhm Max. (Initial value) * Including the resistance of cable. (Measuring method is contact resistance meter.) |
| Insulation resistance | Between live-metallic part and ground: 100 MΩ (at 250 VDC Megger) |
| Dielectric strength | Between live-metallic part and ground: 1000 V (50/60 Hz for 1 min) |
| Durability (Mechanically) | 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
| Durability (Electrically) | 1,000,000 operations Min. (Resistive load 10 mA at 24 VAC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
| Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
| Shock resistance (Destruction) | 1,000 m/s2 |
| Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2. |
| Degree of protection | IEC60529 (JEM): IP40 |
| Mounting specification | Panel mounting |
| Operating Force (OF) | Standard value Max. 0.49 N |
|---|---|
| Over-Travel (OT) | Standard value 1.5 mm Min. |
| Movement Differential (MD) | Standard value 5 um Max. |
| Operating Position (OP) | Reference value 2 mm |
As of August 8, 2016
As of August 8, 2016

As of August 8, 2016
about this Product