Enclosed Switch
Image
| Shape/Structure |
General-purpose Limit switches |
|---|---|
| Actuator |
Sealed plunger 10 dia. Stainless steel plunger |
| Electrical ratings |
4 A at 30 VDC |
| Contact configuration |
Single-Pole, Double-Throw type |
| Load |
General load |
| Cable specifications |
VCTF oil-resistant cable 4 cores (Cable length: 3 m) Diameter: 7.6 mm |
| Degree of protection |
IEC60529 (JEM): IP67 |
As of August 8, 2016
| Shape/Structure | General-purpose Limit switches |
|---|---|
| Service life | General type |
| Operating mechanism | Snap action |
| Actuator | Sealed plunger 10 dia. Stainless steel plunger |
| Electrical ratings | 4 A at 30 VDC |
| Frequency | 50/60 Hz |
| Leakage current | Approx. 1.7 mA |
| Switching mechanism | Self-reset mechanism |
| Contact configuration | Single-Pole, Double-Throw type |
| Contact form | SPDT |
| Load | General load |
| Ratings (DC): Non-Inductive load | Rated voltage: 30 VDC / Resistive load: 4 A(NC) 4 A(NO) / Lamp load: 2 A(NC) 2 A(NO) |
| Ratings (DC): Inductive load | Rated voltage: 30 VDC / Inductive load: 3 A(NC) 3 A(NO) / Motor load: 3 A(NC) 3 A(NO) |
| Inrush current | NC: 20 A NO: 10 A |
| Protective circuit | Classification of protection against electric shock: Class I (with ground terminal) Short-circuit protective device: 10 A fuse type gI or gG (IEC269) |
| Indicator | LED (Light when not operating) Voltage: 30 VDC Leakage current: Approx. 1.7 mA |
| Earth terminal | With ground terminal |
| Cable specifications | VCTF oil-resistant cable 4 cores (Cable length: 3 m) Diameter: 7.6 mm |
| Ambient temperature | Operating: -10 to 70 ℃ |
| Ambient humidity | Operating: 35 to 95% |
| Permissible operating speed | 0.1 mm/s to 0.5 m/s |
|---|---|
| Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
| Permissible operating frequency (Electrically) | 30 operations / 1 minute Max. |
| Contact resistance | 300 mOhm Max. (Initial value) * Including the resistance of cable. (Measuring method is contact resistance meter.) |
| Insulation resistance | Between each terminal of the same polarities: 100 MΩ Between live-metallic part and ground: 100 MΩ Between each terminal and non-live-metallic part: 100 MΩ (at 500 VDC Megger Without LED) |
| Dielectric strength | Between each terminal of the same polarities: 1000 V Between live-metallic part and ground: 1500 V Between each terminal and non-live-metallic part: 1500 V (50/60 Hz for 1 min Without LED) |
| Durability (Mechanically) | 10,000,000 operations Min. (No load) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
| Durability (Electrically) | 1,000,000 operations Min. (Resistive load 1 A at 30 VDC) (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH) |
| Pollution degree | 3 (EN60947-5-1) |
| Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
| Shock resistance (Destruction) | 1,000 m/s2 |
| Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 500 m/s2. |
| Degree of protection | IEC60529 (JEM): IP67 |
| Mounting specification | Front mounting |
| Operating Force (OF) | Standard value Max. 17.65 N |
|---|---|
| Release Force (RF) | Standard value Min. 4.41 N |
| Pre-Travel (PT) | Standard value 1.8 mm Max. |
| Over-Travel (OT) | Standard value 3 mm Min. |
| Movement Differential (MD) | Standard value 0.2 mm Max. |
| Operating Position (OP) | Standard value 24.9 +/- 1 mm |
As of August 8, 2016
As of August 8, 2016

As of August 8, 2016
As of August 8, 2016

NO (white): VCTF oil-resistant cable or VCTF cable., NO (blue): SJT (O) cable approved by UL and CSA. E (yellow/green): VCTF oil-resistant cable., E (green): VCTF cable or SJT (O) cable approved by UL and CSA.
As of August 8, 2016
As of August 8, 2016
Electrical durability curve

As of August 8, 2016
about this Product